Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
M8 Connectors
Created with Pixso.

M12 Inductive Proximity Sensor NPN Normally Closed with 8mm / 10mm Non-flush Detection and IP67 Protection

M12 Inductive Proximity Sensor NPN Normally Closed with 8mm / 10mm Non-flush Detection and IP67 Protection

Brand Name: KRONZ
Model Number: IN8-M12NC68-M0A/D, IN8-M12NC50-M0A/D, IN10-M12NC68-M0A/D, IN10-M12NC50-M0A/D
MOQ: 10 pieces
Price: Negotiable
Packaging Details: Paper box packing
Payment Terms: T/T
Detail Information
Place of Origin:
Guangdong, China
Certification:
CE
IP Rating:
IP67
Sensing Face Material:
PBT
Connection:
M12 Connector
Operating Temperature:
-25...70℃
Model:
NPN N.C
Construction Size:
M12*1mm
Supply Ability:
100000 pieces per month
Highlight:

NPN Normally Closed Proximity Sensor

,

8mm / 10mm Non-flush Inductive Proximity Sensor

,

IP67 M12 Sensor

Product Description
M12 Inductive Proximity Sensor NPN N.C — 8mm / 10mm Non-flush | KRONZ
M12 Inductive Proximity Sensor -- NPN Normally Closed (N.C) Series

8 mm / 10 mm non-flush detection * 10-30 V DC * IP67 * 4-pin M12 connector

Built for fail-safe circuits and wire-break detection. The output is closed during normal operation -- if the cable is cut, the supply drops, or the sensor fails, the output disappears and the PLC stops the line.

Models on this page: IN8-M12NC68-M0A/D, IN8-M12NC50-M0A/D, IN10-M12NC68-M0A/D, IN10-M12NC50-M0A/D

Product Overview
What this series solves

Normally-open sensors hide their faults. If the cable is cut, the connector is loose, or the supply drops, the PLC sees exactly the same state as "no metal present" -- and the line keeps running. The failure is silent until something crashes or a batch goes bad.

NPN normally-closed sensors invert that logic: the output is closed during normal operation, and any abnormal condition causes the output to disappear. The PLC detects "signal lost" and triggers a stop and an alarm. This is the fail-safe principle.

How NPN N.C works

NPN output is current sinking. The internal NPN transistor has its emitter tied to 0 V (L−). The N.C variant inverts the logic of N.O:

  • No metal target -> transistor on -> output pin is pulled to ~0 V, load is energized -> PLC input reads "1"
  • Metal enters the range -> transistor off -> output pin goes high-impedance, load de-energizes -> PLC input reads "0"

The load is wired between L+ (brown, Pin 1) and OUT (black, Pin 4) -- the same wiring position as NPN N.O. Only the internal logic differs. When you retrofit an NPN N.O station with NPN N.C, the cabinet wiring stays as it is.

When to choose NPN N.C
Your situation Choose it?
You need fail-safe -- wire break must trigger an alarm
Used as a safety gate, guard interlock, or in-position check
Detecting that a part has not fallen off / is still in place
PLC input module is sink / common-plus (Japanese PLCs)
You only need a simple "target arrived" check, no safety logic ❌ pick NPN N.O for simplicity
PLC is source / common-minus (Siemens and most European PLCs) ❌ pick PNP N.C
IN8 vs IN10 -- how to pick between the two distances
  • IN8 series -- 8 mm detection range, 500 Hz switching -- faster response
  • IN10 series -- 10 mm detection range, 400 Hz switching -- more installation margin

Both share the M12 × 1 mm cylindrical thread and non-flush (unshielded) installation. Same datasheet, same mounting logic.

Key Features
  • Normally-closed logic -- faults surface, not hide: During normal operation the output stays on. Cable break, M12 connector loose, 24 V supply lost, sensor itself failed -- any of these kills the output and the PLC captures it instantly. Turns "silent failure" into "loud alarm.
  • Designed for safety interlocks and in-position checks: Safety gate closed -> metal flag enters the range -> output opens -> machine allowed to start. Gate opens -> output returns -> safety circuit acts. Same idea for confirming that a workpiece is still in the fixture (drop-out triggers the alarm).
  • Same wiring as NPN N.O -- zero rewiring when you upgrade: The load is wired between L+ and OUT, exactly as on NPN N.O. Upgrading from N.O to N.C requires no wiring change -- only invert the input logic in the PLC program. Retrofit projects are particularly easy.
  • NPN current-sinking, direct to Japanese PLCs: The output plugs straight into the sink input of Mitsubishi, Omron or similar modules -- no interposing relay.
  • Two detection ranges on one page: Choose 8 mm at 500 Hz for high-speed applications, or 10 mm at 400 Hz when the target has more play.
  • Non-flush (unshielded) -- longer range from the same M12 footprint: The unshielded structure lets the magnetic field spread sideways, giving a longer rated range than the flush variant. The trade-off is the free metal space around the sensing face -- see Configuration Details.
  • IP67 + −25…70 °C: IP67 per IEC 60529: dust-tight and protected against temporary immersion. Operating temperature covers −25 °C cold storage to +70 °C cabinet-side mounting.
  • Nickel-plated brass + PBT sensing face: Nickel-plated brass housing for impact and corrosion resistance. Blue PBT sensing face, wear-resistant and insensitive to metal swarf. Two hex nuts (17 mm across flats) resist long-term vibration loosening.
  • Field-replaceable M12 connector + triple electrical protection: 4-pin M12 A-coded male connector (IEC 61076-2-101) for quick cordset replacement on the floor. Built-in short-circuit, reverse-polarity and power-up pulse protection -- the sensor survives commissioning mistakes.
Technical Specifications
Common electrical parameters (all 4 models)
Parameter Specification Standard
Output function NPN, Normally Closed (N.C) IEC 60947-5-2
Output configuration DC 3-wire IEC 60947-5-2
Thread / form factor M12 × 1 mm cylindrical --
Installation type Non-flush (unshielded) IEC 60947-5-2
Operating voltage 10…30 V DC (±10%) IEC 60947-5-2
Voltage drop ≤ 2.0 V IEC 60947-5-2
Rated operating current 200 mA IEC 60947-5-2
Leakage current ≤ 0.01 mA IEC 60947-5-2
No-load current ≤ 10 mA (at 24 V DC) IEC 60947-5-2
Switching hysteresis < 15% of Sr IEC 60947-5-2
Repeat accuracy < 1.0% of Sr IEC 60947-5-2
Electrical protection Short-circuit / reverse-polarity / power-up pulse IEC 60947-5-2
Switching-state indication 4 × LEDs, on while output is active --
Connection 4-pin M12 connector, A-coded IEC 61076-2-101
Per-model differences (key selection parameters)
Model Sensing range Sn Switching freq. Body length Thread length Total length (straight) 90° height
IN8-M12NC68-M0A/D 8 mm (non-flush) 500 Hz 68 mm 42 mm 68 mm 34 mm
IN8-M12NC50-M0A/D 8 mm (non-flush) 500 Hz 50 mm 28 mm 50 mm 20 mm
IN10-M12NC68-M0A/D 10 mm (non-flush) 400 Hz 68 mm 42 mm 68 mm 34 mm
IN10-M12NC50-M0A/D 10 mm (non-flush) 400 Hz 50 mm 28 mm 50 mm 20 mm
Shared across all four: M12 × 1 mm thread, Ø7 mm sensing face, 67 mm barrel length (68-body) or 49 mm (50-body), 17 mm nut across flats.
Mechanical and environmental parameters
Parameter Specification Standard
Ambient operating temperature −25 … +70 °C IEC 60068-2-14
Ingress protection IP67 (dust-tight, protected against temporary immersion) IEC 60529
Housing material Brass, nickel-plated --
Sensing face material PBT (polybutylene terephthalate) --
Connector thread M12 × 1 mm male IEC 61076-2-101
Mounting hardware Two hex nuts, 17 mm across flats --
NPN N.C output truth table
Metal target Output transistor Output pin level LEDs PLC input
Not in range On ≈ 0 V Lit 1
Enters range Off (high-Z) Pulled up to L+ Off 0
Wire break / power loss / sensor fault No output -- Off 0 -> alarm
Note the last row -- that is exactly what normally-closed brings to a safety circuit.
Configuration Details
Model selection
Model Range Frequency Body Recommended use
IN8-M12NC68-M0A/D 8 mm 500 Hz 68 mm Safety-gate interlock, high-speed station presence check
IN8-M12NC50-M0A/D 8 mm 500 Hz 50 mm Slim fixtures, tight safety points
IN10-M12NC68-M0A/D 10 mm 400 Hz 68 mm Vibration-tolerant guard doors, generous safety margin
IN10-M12NC50-M0A/D 10 mm 400 Hz 50 mm Limited space with 10 mm range required
Pin assignment -- 4-pin M12 A-coded
Pin Wire colour (typical) Signal Description
1 Brown L+ Supply positive, 10…30 V DC
2 White N/C Not connected (reserved)
3 Blue L− Supply 0 V (GND)
4 Black OUT NPN Normally Closed (N.C) switching output
Data note: The factory datasheet does not include a wiring diagram. The table above follows the M12 4-pin A-coded convention (IEC 61076-2-101). Verify against the wiring label packed with the sensor before commissioning.
Wiring diagram -- NPN N.C
NPN Normally Closed proximity sensor wiring diagram showing load connection between L+ and OUT pins

Key point: The wiring position is identical to NPN N.O (load between L+ and OUT). Only the internal logic differs -- output is closed when no metal is present, and opens when metal arrives.

Safety-circuit application example
Safety circuit application example showing proximity sensor in safety interlock configuration
Important: For personnel protection, a single sensor is not a substitute for a safety-rated circuit compliant with ISO 13849 / IEC 62061. Use this series for general industrial interlocks and fault alarming; consult engineering for safety-rated applications.
Dimensions (mm)
Dimension 68 mm body 50 mm body
Total length (straight M12 connector) 68 50
Barrel length (to connector shoulder) 67 49
Threaded section length 42 28
Sensing face diameter Ø7 Ø7
90° right-angle connector height 34 20
Mounting thread M12 × 1 mm M12 × 1 mm
Nut across flats 17 17
Mounting requirements (non-flush)
  • Free metal space around the sensing face. Non-flush sensors let the magnetic field expand sideways. Without sufficient clearance, the effective range collapses. Recommended free space ≥ 3 × Sn (≈ 24 mm for the 8 mm body, ≈ 30 mm for the 10 mm body). Side-by-side sensors also need adequate spacing to prevent mutual interference.
  • If you must flush-mount. This series is unshielded. Switch to a flush (shielded) variant if side clearance is impossible.
  • Tightening torque. Suggested maximum 15 N*m to avoid housing deformation.
  • Safety-point placement. Mount interlocks where they cannot be easily struck. Consider a protective bracket. Route the cable away from power conductors.
Typical applications
Industry Use case
Safety guarding Safety-gate / guard-door interlock, light-curtain bypass confirmation
Industrial automation Workpiece in-position check (drop-out triggers alarm), fixture-clamp confirmation
Packaging machinery Guard in-place, foil / carton missing detection
Material handling Pallet in-position, stack-height over-limit detection
Machine tools Guard interlock, tool in-position detection
Robotics Safety-fence gate status, gripper part-retention confirmation
Related variants in the same M12 series
Output function Description
NPN Normally Open (N.O) Output closes when metal arrives -- simplest logic
PNP Normally Open (N.O) Current-sourcing output, fits Siemens and other European PLCs
PNP Normally Closed (N.C) Sourcing + fail-safe
Data Provenance and Assumption Log
  • Factory-measured values (cited directly from datasheet): operating voltage 10…30 V DC (±10%), voltage drop ≤ 2.0 V, operating current 200 mA, leakage current ≤ 0.01 mA, no-load current ≤ 10 mA (24 V), hysteresis < 15% Sr, repeat accuracy < 1.0% Sr, triple electrical protection, 4 × LED indication, −25…70 °C, IP67, brass nickel-plated + PBT, M12 connector, M12 × 1 mm thread, 8 mm / 10 mm non-flush, 500 Hz / 400 Hz, all dimensional values.
  • Standard-derived values (datasheet not specified; per IEC 60947-5-2): response time, standard target (Fe37), correction factors for non-ferrous metals. Not stated on this page; request confirmation from engineering before publishing.
  • Engineering guidance (not datasheet figures): free space ≥ 3 × Sn, nut torque ≤ 15 N*m. Labelled "suggested" in the text.
  • Safety-rating statement: This series is not certified to ISO 13849 / IEC 62061. The notes above clearly mark this; no safety-rating claim is made.