Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
M8 Connectors
Created with Pixso.

M12 Inductive Proximity Sensor with 8mm / 10mm Non-flush Detection and PNP Normally Closed (N.C) Output - IP67 Protected

M12 Inductive Proximity Sensor with 8mm / 10mm Non-flush Detection and PNP Normally Closed (N.C) Output - IP67 Protected

Brand Name: KRONZ
Model Number: IN8-M12PC68-M0A/D, IN8-M12PC50-M0A/D, IN10-M12PC68-M0A/D, IN10-M12PC50-M0A/D
MOQ: 10 pieces
Price: Negotiable
Packaging Details: Paper box packing
Payment Terms: T/T
Detail Information
Place of Origin:
Guangdong, China
Certification:
CE
Standard:
IEC 60947-5-2
Output Function:
PNP, Normally Closed (N.C)
Output Configuration:
DC 3-wire
Thread / Form Factor:
M12 × 1 Mm Cylindrical
Installation Type:
Non-flush (unshielded)
Rated Operating Current:
200 MA
Connection:
4-pin M12 Connector, A-coded
Switching Freq.:
500 Hz/500 Hz
Supply Ability:
100000 pieces per month
Highlight:

8mm / 10mm non-flush detection Inductive Proximity Sensor

,

PNP Normally Closed (N.C) M12 Sensor

,

IP67 protection Inductive Proximity Sensor

Product Description
M12 Inductive Proximity Sensor PNP N.C — 8mm / 10mm Non-flush | KRONZ
M12 Inductive Proximity Sensor -- PNP Normally Closed (N.C) Series
8 mm / 10 mm non-flush detection * 10-30 V DC * IP67 * 4-pin M12 connector
One-line positioning: The fail-safe choice for European PLCs and export-bound equipment. PNP current-sourcing output combined with normally-closed logic -- the output stays at 24 V during normal operation, and any wire break, supply loss, or sensor fault kills the output and triggers the alarm.
Models on this page: IN8-M12PC68-M0A/D, IN8-M12PC50-M0A/D, IN10-M12PC68-M0A/D, IN10-M12PC50-M0A/D
Product Overview
What this series solves
Normally-open sensors hide their faults. If the cable is cut, the connector is loose, or the supply drops, the PLC sees exactly the same state as "no metal present" -- and the line keeps running. The failure is silent until something crashes or a batch goes bad.
PNP normally-closed sensors invert that logic: the output sources 24 V during normal operation, and any abnormal condition causes the output to disappear. The PLC detects "voltage lost" and triggers a stop and an alarm. This is the fail-safe principle, delivered on the source (PNP) side for European PLCs and export equipment.
How PNP N.C works
PNP output is current sourcing. The internal PNP transistor has its emitter tied to L+. The N.C variant inverts the logic of N.O:
  • No metal target -> transistor on -> output pin sources ~L+ (24 V), load is energized -> PLC input reads "1"
  • Metal enters the range -> transistor off -> output pin goes high-impedance, load de-energizes -> PLC input reads "0"
The load is wired between OUT (black, Pin 4) and L− (blue, Pin 3) -- the same wiring position as PNP N.O. Only the internal logic differs. When you retrofit a PNP N.O station with PNP N.C, the cabinet wiring stays as it is.
When to choose PNP N.C
Your situation Choose it?
You need fail-safe -- wire break must trigger an alarm
PLC input module is source / common-minus (Siemens, Beckhoff and other European PLCs)
Equipment is exported to Europe or North America with safety logic
Used as a safety gate, guard interlock, or in-position check
You only need a simple "target arrived" check, no safety logic ❌ pick PNP N.O for simplicity
PLC is sink / common-plus (Mitsubishi, Omron, Japanese PLCs) ❌ pick NPN N.C
IN8 vs IN10 -- how to pick between the two distances
  • IN8 series -- 8 mm detection range, 500 Hz switching -- faster response
  • IN10 series -- 10 mm detection range, 400 Hz switching -- more installation margin
Both share the M12 × 1 mm cylindrical thread and non-flush (unshielded) installation. Same datasheet, same mounting logic.
Key Features
1. Normally-closed logic -- faults surface, not hide
During normal operation the output sources 24 V. Cable break, M12 connector loose, 24 V supply lost, sensor itself failed -- any of these kills the output and the PLC captures it instantly. Turns "silent failure" into "loud alarm."
2. PNP current-sourcing, direct to European PLCs
The output plugs straight into the source input of Siemens S7, Beckhoff, or Schneider modules -- no interposing relay, no level shifter. Drop-in for export-bound equipment.
3. Designed for safety interlocks and in-position checks
Safety gate closed -> metal flag enters the range -> output opens -> machine allowed to start. Gate opens -> output returns -> safety circuit acts. Same idea for confirming that a workpiece is still in the fixture (drop-out triggers the alarm).
4. Same wiring as PNP N.O -- zero rewiring when you upgrade
The load is wired between OUT and L−, exactly as on PNP N.O. Upgrading from N.O to N.C requires no wiring change -- only invert the input logic in the PLC program. Retrofit projects are particularly easy.
5. Two detection ranges on one page
Choose 8 mm at 500 Hz for high-speed applications, or 10 mm at 400 Hz when the target has more play.
6. Non-flush (unshielded) -- longer range from the same M12 footprint
The unshielded structure lets the magnetic field spread sideways, giving a longer rated range than the flush variant. The trade-off is the free metal space around the sensing face -- see Configuration Details.
7. IP67 + −25…70 °C
IP67 per IEC 60529: dust-tight and protected against temporary immersion. Operating temperature covers −25 °C cold storage to +70 °C cabinet-side mounting.
8. Nickel-plated brass + PBT sensing face
Nickel-plated brass housing for impact and corrosion resistance. Blue PBT sensing face, wear-resistant and insensitive to metal swarf. Two hex nuts (17 mm across flats) resist long-term vibration loosening.
9. Field-replaceable M12 connector + triple electrical protection
4-pin M12 A-coded male connector (IEC 61076-2-101) for quick cordset replacement on the floor. Built-in short-circuit, reverse-polarity and power-up pulse protection -- the sensor survives commissioning mistakes.
Technical Specifications
Common electrical parameters (all 4 models)
Parameter Specification Standard
Output function PNP, Normally Closed (N.C) IEC 60947-5-2
Output configuration DC 3-wire IEC 60947-5-2
Thread / form factor M12 × 1 mm cylindrical --
Installation type Non-flush (unshielded) IEC 60947-5-2
Operating voltage 10…30 V DC (±10%) IEC 60947-5-2
Voltage drop ≤ 2.0 V IEC 60947-5-2
Rated operating current 200 mA IEC 60947-5-2
Leakage current ≤ 0.01 mA IEC 60947-5-2
No-load current ≤ 10 mA (at 24 V DC) IEC 60947-5-2
Switching hysteresis < 15% of Sr IEC 60947-5-2
Repeat accuracy < 1.0% of Sr IEC 60947-5-2
Electrical protection Short-circuit / reverse-polarity / power-up pulse IEC 60947-5-2
Switching-state indication 4 × LEDs, on while output is active --
Connection 4-pin M12 connector, A-coded IEC 61076-2-101
Per-model differences (key selection parameters)
Model Sensing range Sn Switching freq. Body length Thread length Total length (straight) 90° height
IN8-M12PC68-M0A/D 8 mm (non-flush) 500 Hz 68 mm 42 mm 68 mm 34 mm
IN8-M12PC50-M0A/D 8 mm (non-flush) 500 Hz 50 mm 28 mm 50 mm 20 mm
IN10-M12PC68-M0A/D 10 mm (non-flush) 400 Hz 68 mm 42 mm 68 mm 34 mm
IN10-M12PC50-M0A/D 10 mm (non-flush) 400 Hz 50 mm 28 mm 50 mm 20 mm
Shared across all four: M12 × 1 mm thread, Ø7 mm sensing face, 67 mm barrel length (68-body) or 49 mm (50-body), 17 mm nut across flats.
Mechanical and environmental parameters
Parameter Specification Standard
Ambient operating temperature −25 … +70 °C IEC 60068-2-14
Ingress protection IP67 (dust-tight, protected against temporary immersion) IEC 60529
Housing material Brass, nickel-plated --
Sensing face material PBT (polybutylene terephthalate) --
Connector thread M12 × 1 mm male IEC 61076-2-101
Mounting hardware Two hex nuts, 17 mm across flats --
PNP N.C output truth table
Metal target Output transistor Output pin level LEDs PLC input
Not in range On ≈ L+ (24 V) Lit 1
Enters range Off (high-Z) 0 V (pulled down by load) Off 0
Wire break / power loss / sensor fault No output -- Off 0 -> alarm
Note the last row -- that is exactly what normally-closed brings to a safety circuit.
Configuration Details
Model selection
Model Range Frequency Body Recommended use
IN8-M12PC68-M0A/D 8 mm 500 Hz 68 mm Safety-gate interlock, high-speed station presence check
IN8-M12PC50-M0A/D 8 mm 500 Hz 50 mm Slim fixtures, tight safety points
IN10-M12PC68-M0A/D 10 mm 400 Hz 68 mm Vibration-tolerant guard doors, generous safety margin
IN10-M12PC50-M0A/D 10 mm 400 Hz 50 mm Limited space with 10 mm range required
Pin assignment -- 4-pin M12 A-coded
Pin Wire colour (typical) Signal Description
1 Brown L+ Supply positive, 10…30 V DC
2 White N/C Not connected (reserved)
3 Blue L− Supply 0 V (GND)
4 Black OUT PNP Normally Closed (N.C) switching output
Data note: The factory datasheet does not include a wiring diagram. The table above follows the M12 4-pin A-coded convention (IEC 61076-2-101). Verify against the wiring label packed with the sensor before commissioning.
Safety-circuit application example
Safety gate CLOSED -> metal flag enters range -> N.C output OPENS -> machine may start
Safety gate OPEN -> metal flag leaves range -> N.C output CLOSES -> machine stops
Cable cut / 24 V lost / sensor fault
-> output disappears -> instant stop and alarm (fail-safe)
Dimensions (mm)
Dimension 68 mm body 50 mm body
Total length (straight M12 connector) 68 50
Barrel length (to connector shoulder) 67 49
Threaded section length 42 28
Sensing face diameter Ø7 Ø7
90° right-angle connector height 34 20
Mounting thread M12 × 1 mm M12 × 1 mm
Nut across flats 17 17
Mounting requirements (non-flush)
  • Free metal space around the sensing face. Non-flush sensors let the magnetic field expand sideways. Without sufficient clearance, the effective range collapses. Recommended free space ≥ 3 × Sn (≈ 24 mm for the 8 mm body, ≈ 30 mm for the 10 mm body). Side-by-side sensors also need adequate spacing to prevent mutual interference.
  • If you must flush-mount. This series is unshielded. Switch to a flush (shielded) variant if side clearance is impossible.
  • Tightening torque. Suggested maximum 15 N*m to avoid housing deformation.
  • Safety-point placement. Mount interlocks where they cannot be easily struck. Consider a protective bracket. Route the cable away from power conductors.
Typical applications
Industry Use case
Safety guarding Safety-gate / guard-door interlock, light-curtain bypass confirmation
Industrial automation Workpiece in-position check (drop-out triggers alarm), fixture-clamp confirmation
Packaging machinery Guard in-place, foil / carton missing detection
Material handling Pallet in-position, stack-height over-limit detection
Machine tools Guard interlock, tool in-position detection
Export equipment European / American PLC integration with fail-safe logic
Robotics Safety-fence gate status, gripper part-retention confirmation
Related variants in the same M12 series
Output function Description
PNP Normally Open (N.O) Sourcing, output at 24 V when metal arrives
NPN Normally Open (N.O) Current-sinking output, fits Japanese PLCs
NPN Normally Closed (N.C) Sinking + fail-safe