Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
M8 Connectors
Created with Pixso.

M12 A-Coded 12-Pin Female Field Wirable Connector with IP67 Protection and 90° Angled Design

M12 A-Coded 12-Pin Female Field Wirable Connector with IP67 Protection and 90° Angled Design

Brand Name: KRONZ
Model Number: H1212FA-7/H1212FA-9
MOQ: 10 pieces
Price: Negotiable
Packaging Details: Paper box packing
Payment Terms: T/T,Western Union
Detail Information
Place of Origin:
Guangdong, China
Certification:
CE
Application:
Industrial Automation, Sensors, Actuators
Contacts:
0.5m Pre-wired
Rated Current:
3A
Ip Rate:
IP67
Connector Contacts:
Alloy, Brass, Gold-plated
Pin Option:
12Pin
Connector Insert:
Plastic, PA, Black
Locking Mechanism:
Screw Lock
Operating Voltage:
Up To 250V
Standard:
IEC 61076-2-104
Wire Color:
1=BN,3=BU,4=BK
Cable Length:
Customized
Cable:
Shielded
Supply Ability:
100000 pieces per month
Highlight:

M12 A-Coded female connector IP67

,

12-pin field wirable connector 90° angled

,

M12 female connector with IP67 protection

Product Description
M12 A-Coded 12-Pin Female Field Wirable Connector with IP67 Protection
The M12 A-Coded 12-Pin Female Field Wirable Assembly, Angled (90°) is a right-angle industrial circular connector designed for applications where cable exit direction must be perpendicular to the mating axis — enabling installation in tight spaces, behind panels, and in dense wiring environments. Manufactured to IEC 61076-2-101, this connector delivers IP67 environmental protection with high-density 12-pin capacity in a compact elbow form factor.
The housing crimp base is constructed from zinc alloy with nickel plating for superior corrosion resistance in harsh environments. The connector nut uses alloy/brass with nickel plating, and contacts are gold-plated brass for low contact resistance (≤5mΩ) and reliable signal transmission over 100+ mating cycles. Screw-type termination accepts cables of 4–6mm (PG7) or 6–8mm (PG9) diameter — no crimping tools required. FPM/FKM (fluoroelastomer) seals maintain IP67 protection across the full operating range of -25°C to +85°C.
With overall dimensions of approximately 40mm * 38mm and an outer diameter of 20.2mm, the angled design redirects the cable 90° from the mating face, making it ideal for back-of-panel wiring, confined enclosures, and installations where straight connectors would cause cable bending stress.
Key Features
  • IP67 Environmental Protection - Fully dust-tight and waterproof. Withstands immersion in 1 meter of water for 30 minutes. FPM/FKM elastomer seals resist oil, coolant, and chemical exposure for long-term sealing integrity.
  • 90° Angled Cable Exit - Right-angle design redirects cable perpendicular to the connector axis. Eliminates cable bending stress in tight spaces, behind panels, and in dense installation environments.
  • 12-Pin High-Density Configuration - Twelve independent circuits in a single M12 connector footprint. Supports multi-sensor arrays, signal distribution, and complex I/O wiring while reducing connector count and panel space.
  • Gold-Plated Brass Contacts - Brass contacts with gold plating deliver ≤5mΩ contact resistance and ≥100MΩ insulation resistance, ensuring stable signal integrity in noise-sensitive industrial environments.
  • Field-Wirable — No Crimping Tools - Screw termination accepts 4–6mm (PG7) or 6–8mm (PG9) cable diameter. Strip, insert, tighten — complete wiring on-site in under 10 minutes.
Technical Specifications
Parameter Specification
Applicable Standard IEC 61076-2-101
Connector Type M12 A-Coded Female, Field Wirable, Angled (90°)
Pin Count 12
Thread Size M21*1
Overall Width ~40 mm
Overall Height ~38 mm
Outer Diameter Ø 20.2 mm
Housing Crimp Base Material Zinc Alloy, Nickel-Plated
Connector Nut Material Alloy / Brass, Nickel-Plated
Contact Material Gold-Plated Brass
Contact Carrier Material PA (Polyamide), Black
Sealing Material FPM / FKM (Fluoroelastomer)
Rated Current 1.5A
Rated Voltage 30V
Insulation Resistance ≥ 100 MΩ
Contact Resistance ≤ 5 mΩ
Pollution Degree 3
Operating Temperature -25°C to +85°C
Mechanical Life > 100 Mating Cycles
IP Rating IP67
Coding A-Coded
Termination Type Screw Connection
Cable Exit Diameter 4–6mm (PG7) / 6–8mm (PG9)
Dimensions
  • Thread Standard: M21*1
  • Overall Width: ~40 mm
  • Overall Height: ~38 mm
  • Outer Diameter: Ø 20.2 mm
  • Cable Exit: 4–6mm (PG7) / 6–8mm (PG9)
  • Orientation: Angled (90°)
  • Mating Compatibility: All M12 A-Coded 12-Pin Male Connectors
Pin Layout (12-Pin A-Coded Female)
The 12-pin configuration arranges contacts in a single circle inside the M12 female housing, following IEC 61076-2-101 A-Coded standard:
  • 12 pins evenly distributed in a circular pattern
  • Standard A-Coded keyway positioning (female)
  • Fully compatible with any M12 A-Coded 12-pin male connector from all major manufacturers
Applications
The 12-pin M12 angled female connector is specifically designed for applications where space constraints require a 90° cable exit:
  • Tight-Space Sensor Wiring: Back-of-panel connections where straight connectors would cause cable bending or exceed bend radius limits
  • Dense Control Cabinets: High-density I/O panels where perpendicular cable routing maximizes space efficiency and airflow
  • Multi-Sensor Junction Boxes: Aggregating signals from 12 sensors at a single junction point in confined enclosures
  • Robotics & Motion Systems: Feedback wiring for multi-axis motor controllers and encoder clusters in tight mechanical assemblies
  • Process Automation: Sensor arrays for temperature, pressure, proximity, and level monitoring where cable management is critical
  • Conveyor Systems: Centralized sensor wiring along conveyor lines where cables must exit perpendicular to avoid interference with moving parts
  • HVAC & Building Automation: Multi-zone thermostat and damper control connections inside compact control panels
  • Agricultural Machinery: Sensor arrays for soil moisture, temperature, and GPS guidance where cables must route along machinery frames
  • Water & Wastewater Treatment: IP67-rated multi-channel connections for level sensors, pH probes, and flow meters in wet environments with limited cable routing space
  • Food & Beverage Processing: Washdown-rated installations where angled cable exit prevents water pooling at the connector interface
Angled vs. Straight: When to Choose the 90° Version
Factor Angled (90°) Straight (0°)
Cable exit direction Perpendicular to mating axis In-line with mating axis
Space behind panel Requires less depth Requires more depth
Cable bend stress Eliminates sharp bends May require external bend relief
Dense panel installations Ideal for side-by-side connectors May cause cable interference
Washdown environments Cable routes downward, reducing water ingress risk Cable may pool water at connector
Aesthetic routing Cleaner cable management along surfaces Cables extend straight out
Choose the angled version when space is limited behind the panel, when cables need to route along a surface rather than protruding, or when multiple connectors are installed side by side and cable interference is a concern.
Installation Guide
  1. Prepare the cable: Strip the outer jacket to expose 12 individual conductors. Ensure total cable diameter matches the gland size — 4–6mm for PG7 or 6–8mm for PG9.
  2. Thread the components: Pass the cable through the coupling nut, cable gland insert (PA), and FPM sealing ring in the correct order.
  3. Terminate the wires: Insert each of the 12 conductors into its designated female pin terminal. Tighten each screw — avoid overtightening to prevent contact damage.
  4. Assemble the housing: Slide the female connector housing over the terminated contacts, aligning the A-Coded keyway notch.
  5. Seal and tighten: Thread the coupling nut onto the M21*1 housing thread. Tighten by hand until the FPM seal compresses uniformly around the cable.
  6. Verify: Check all 12 pins are seated, housing is fully threaded, and cable cannot be pulled out. Test continuity on all 12 circuits before commissioning.
  7. Orient the connector: The 90° angled body allows you to rotate the connector to the desired cable exit direction before final tightening.
Complete Product Range — M12 A-Coded Female Field Wirable, Angled (90°)
Pin Layout Pins Connection Coding Current Voltage Angle Cable Ø Part Number
○○○ 3 Screw A-CODE 4A 250V Angled 4–6mm (PG7) H1203FA-7
○○○ 3 Screw A-CODE 4A 250V Angled 6–8mm (PG9) H1203FA-9
○○○○ 4 Screw A-CODE 4A 250V Angled 4–6mm (PG7) H1204FA-7
○○○○ 4 Screw A-CODE 4A 250V Angled 6–8mm (PG9) H1204FA-9
○○○○○ 5 Screw A-CODE 4A 60V Angled 4–6mm (PG7) H1205FA-7
○○○○○ 5 Screw A-CODE 4A 60V Angled 6–8mm (PG9) H1205FA-9
○○○○○○○○ 8 Screw A-CODE 2A 30V Angled 4–6mm (PG7) H1208FA-7
○○○○○○○○ 8 Screw A-CODE 2A 30V Angled 6–8mm (PG9) H1208FA-9
○○○○○○○○○○○○ 12 Screw A-CODE 1.5A 30V Angled 4–6mm (PG7) H1212FA-7
○○○○○○○○○○○○ 12 Screw A-CODE 1.5A 30V Angled 6–8mm (PG9) H1212FA-9
Frequently Asked Questions
Q1: What is the rated current and voltage for the 12-pin M12 angled female connector?
The 12-pin M12 A-Coded angled female connector is rated at 1.5A per pin at 30V AC/DC. The reduced current and voltage ratings compared to lower pin counts (e.g., 3/4-pin at 4A/250V) are due to the smaller contact size and tighter pin spacing required to fit 12 pins within the M12 housing. It is designed for signal-level and low-power applications, not for power distribution.
Q2: What does "angled" or "90°" mean for this connector?
The angled (90°) version redirects the cable exit perpendicular to the connector's mating axis. Instead of the cable extending straight back from the connector, it exits at a right angle. This is ideal for installations behind panels, in tight enclosures, or where cables need to route along a surface rather than protruding outward. The angled design also reduces cable bending stress and can help prevent water pooling at the connector interface in washdown environments.
Q3: What is the difference between PG7 and PG9 cable glands?
PG7 and PG9 refer to the cable gland size standard. PG7 accepts cables with an outer diameter of 4–6mm, while PG9 accepts cables with an outer diameter of 6–8mm. Choose the gland size that matches your cable's outer diameter for proper sealing and strain relief. Using the wrong gland size will compromise the IP67 rating — a PG7 gland with an 8mm cable will not seal, and a PG9 gland with a 4mm cable will not grip properly.
Q4: Is the 12-pin M12 angled female connector compatible with 8-pin or 5-pin male connectors?
No. The 12-pin M12 A-Coded female connector only mates with 12-pin A-Coded male connectors. M12 connectors with different pin counts have different keyway positions and pin arrangements — they are physically incompatible by design. This prevents incorrect connections that could damage equipment or create safety hazards. The angled or straight orientation does not affect mating compatibility.
Q5: Can this 12-pin connector carry digital signals like IO-Link?
Yes. The 12-pin M12 A-Coded angled female connector supports digital signal transmission including IO-Link, PROFINET, and other industrial communication protocols at signal level. However, for high-speed data protocols like Ethernet (100 Mbps+), consider using D-Coded or X-Coded M12 connectors which are optimized for data transmission. The 12-pin A-Coded connector is best suited for standard sensor-level signals, DC power, and low-speed digital I/O.
Q6: What is the difference between 12-pin A-Coded and 12-pin X-Coded?
Both support 12 pins, but they serve different purposes. A-Coded connectors are designed for sensor/actuator signal wiring at low voltage (30V, 1.5A). X-Coded connectors are designed for high-speed data transmission (up to 10 Gbps) and are not interchangeable with A-Coded. They have different keyways and cannot be mated with each other.
Q7: How do I verify IP67 sealing after field installation?
After wiring, ensure: (1) the FPM/FKM sealing ring is seated evenly around the cable with no gaps; (2) the coupling nut is hand-tightened until the cable cannot move; (3) the housing thread is fully engaged with no cross-threading. For angled connectors, also verify that the 90° body orientation is correct for your cable routing direction before final tightening. IP67 rating is only guaranteed when the connector is properly assembled and mated with a compatible male connector.
Q8: What materials are used in this connector?
The connector nut is made of alloy/brass with nickel plating. Contacts are gold-plated brass. The contact carrier is black PA (polyamide) plastic. The crimp base housing is zinc alloy with nickel plating. Sealing uses FPM/FKM (fluoroelastomer) rings that resist oils, chemicals, and UV from -25°C to +85°C.
Q9: When should I choose angled over straight?
Choose the angled version when: space is limited behind the panel or enclosure; cables need to route along a surface rather than protruding straight out; multiple connectors are installed side by side and straight cables would interfere with each other; you want to reduce cable bending stress at the exit point; or in washdown environments where a downward cable exit prevents water from pooling at the connector interface.